Edan M50 ® Vital Signs Monitor
Vital signs monitor edan m50 ® ecg, spo2, resp, nibp, 2-temp, pr.
Oximetry with pulse tone modulation. Arrhythmia analysis. Internal rechargeable lithium battery. Connection to central monitoring. Pacemaker Detection. Nurse call.


Qty


Descripción

CE Safety Standards in accordance with Directive Council 2007/47 / CE relative to Medical products. IEC 60601-1 + A1 + A2, IEC 60601-1-2 + A1.

• Physical Specifications: Dimensions: 260mm (L) x 140mm (W) x 205mm (H). Weight: Normal Configuration; 3.6 kg.

• Screen: 8.4 "color TFT LCD (optional touch screen). Resolution: 800 x 600 dpi. Number of waves: up to 8. Waveform display: up to 11.

• Selectable interface: Standard screen. Screens Large letters for intensive care. Representation of curves, graph and trends.

• Bed-to-bed viewing on screen (optional). Dynamic oxicardiorespirography seen on screen. Dosage calculation interface for drugs. Sweep speed: 12.5mm / s, 25mm / s, 50mm / s

• Operating environment: Temperature: Storage 20-55 ° C Work 5-40 ° C.

• Humidity: Storage 25 %-93% (No condensation). Work 25 %-80% (No condensation).

• Power supply: External power supply: AC 100-240V, 50 / 60HZ Pmax: 80VA

• Internal power battery: Type: Lithium rechargeable battery. Voltage: 14.8V DC. Capacity: 5000 mAh.

• Battery working period: Up to 7 hours. Loading time

• Breathing: Method: Transthoracic impedance. Operation Mode: Auto / Manual RR Measurement Range: Adult: 0 ~ 120 rpm Neonate / Pediatric: 0 ~ 150 rpm Resolution: 1 rpm

• Apnea threshold alarm: 10s, 15s, 20s (default), 25s, 30s, 35s, 40s. Alarm: Yes, acoustic and visual alarm revocable alarm events. Bandwidth: 0.2-2.5 Hz (-3 dB) Sweep speed: 12.5 mm / s.


Información Técnica

• ECG: Leads: 5 leads and 3 leads

• 3 leads of the cable: RA; THE; LL or R, L, F. 5 leads of the cable: RA; THE; RL, LL, V or R, L, N, F,

• Cable selection: 3 leads: I, II, III. leads: I, II, III, aVR, aVL, aVF, V.

• Selectable gain: x0.125, x0.25, x0.5, auto. Scanning speed: 12.5mm / s, 25mm / s, 50mm / s HR ECG Range: Adult and pediatric: 15-300bpm. Neonate: 15-350bpm. Resolution and precision: + -1 bpm 0 + -1% whatever

• Filters: Diagnostic mode: 0.05-150Hz. Monitoring mode: 0.5 to 40 Hz. Surgery mode: 1-20Hz. ST segment detection: Measurement range: -2.0mV ~ 2.0mV. Alarm range: -2.0 mV ~ 2.0mV. ST segment arrhythmia analysis and categorization.

• Alarms: Audible and visual alarm detectable abnormal IEC 60601-2-25; AAMI CE 11 / EC 13; IEC 60601-2-27 NIBP: Method: Automatic oscillometric. Operating modes: manual / automatic /

• Automatic time interval measurement: Adjustable 1/2/3/4/5/10/15/30/60/90/120/240/480 minutes.

• Measurement unit: mm CmH2O selectable. Measurement type: systolic, diastolic, mean Pressure range for adults:

• Systolic: 40 to 270 mmHg. Diastolic: 10 to 215 mmHg. Medium: 20 to 235 mmHg. Pediatric pressure range: Systolic: 40 - 200 mmHg. Diastolic: 10-150 mmHg. Medium: 20 to 165 mmHg.

• Pressure range for neonates: Systolic: 40 - 135 mmHg. Diastolic: 10-100 mmHg. Medium: 20 - 110 mmHg.

• Leak test and automatic pressure calibration:

• Protection against excessive pressure. Resolution: 1 mm Hg. Accuracy: Maximum mean error of ± 5 mmHg.

• Standard deviation of ± 8 mm Hg. Alarm: systolic, diastolic, average. NIBP PR: Measure 40 ~ 240 beats per minute


• Resolution: 1 bpm. Accuracy: ± 3bpm or 3% whichever is greater.

• EDAN SpO2: Measurement and alarm range: 0 - 100%. Resolution: 1%. Accuracy: ± 2% (70-100%, Adult / Pediatric). ± 3% (70-100%, Neonate). PR Measurement and Alarm Range: 30 - 300bpm. Resolution: 1 ppm. Accuracy: 2bpm. Refresh rate: 1s. ISO 9919

• Nellcor SpO2 (optional): Measurement and alarm range: 0 - 100%. Resolution: 1%. Accuracy: ± 2.3% (70-100%, Adult / Pediatric). ± 3 %-3 .5% (70-100%, Neonate). Measurement and PR alarm range: 20 - 300 bpm. resolution: 1 bpm. Accuracy: 3bpm (depends on the probe). Refresh rate: 1s.

• ISO 9919

• Temperature (2 channels, one probe by default)


M50